♨️ ONDOHL Electric Boiler Guide

user guide

Powered by Google Nest / Model: ONDOHL Canvas One

Welcome! Your heating system powered by the ONDOHL LLC is fully integrated with a Google Nest Smart Thermostat. Here is a quick guide on how to operate the system and important safety instructions.

♨️ About ONDOHL Heating System

About Your Heating System

The ONDOHL Electric Boiler installed in your home is a custom-engineered, American-market version of a proven heating system.

Expert Manufacturing

Manufactured in partnership with Suntech Industry, a trusted Korean manufacturer with over 15 years of experience specializing in electric boilers, heating components, and OEM production for leading brands like Kiturami Boiler.

Tailored for Your Home

Redesigned specifically to meet US electrical standards while seamlessly integrating with Google Nest Smart Thermostat for maximum efficiency and safety.

Safety First

Built with built-in overheat protection and automatic water level sensors to ensure quiet, safe, and reliable heating throughout the season.

♨️ Google Nest Thermostat

Basic Operation

How to Adjust Temperature

On the Thermostat: Swipe up or down on the right side touch bar to adjust the target temperature. Tap the side bar to select/confirm.

On your Phone: Adjust the temperature, change modes, or set schedules anytime using the Google Home app.

Recommended Temperatures

Comfort: 68°F – 72°F

Sleeping / Away: 62°F – 65°F

 

Smart Energy Saving

The system automatically uses phone location/sensors to detect when you leave and switches to Eco Temperature to save energy. You don’t need to turn the boiler off manually when leaving

⚠️️ Product and pre-settings

the key internal components

1. Water Expansion & Supply Tank (Top Left)

  • What it is: The translucent white plastic container on the top left.

  • Function: Holds the heating water supply and absorbs thermal expansion as the water heats up.

  • User Line ([WATER LEVEL]): Indicates the maximum water refill level. Overfilling can cause overflow when the water expands during heating.

2. Main Heating Tank & Element (Bottom Right - White Tank)

  • What it is: The vertical white cylindrical container housing the internal electric heating element.

  • Function: Water passes through this tank where the electric immersion heater quickly warms it before it is pumped into your radiant floor or radiator loop.

  • Note (DO NOT TOUCH): During the operation it gets hot.

3. Water Circulation Pump (Bottom Left)

  • What it is: The black pump unit located at the lower left.

  • Function: Actively circulates hot water out through the heating loop and pulls cooler return water back through the boiler.

4. Nest Control Relay / Switcher (Bottom Center-Left)

  • What it is: The small electronics module at the bottom.

  • Function: Bridges the 24V signals from the Google Nest Thermostat to trigger the boiler’s main power circuit (240V/120V) on and off based on room temperature demands.

5. Control Panel & Status Indicators (Top Right)

  • Orange Light ([Orange Light]): Master power indicator showing the main electrical circuit is powered.

  • Green Light ([GREEN LIGHT]): Active status indicator showing the heating element is energized and heating safely.

  • Red Light ([RED LIGHT]): Warning/Fault indicator triggered if the water level drops too low or if an overheat condition occurs.

  • Dial ([DO NOT TOUCH] Water Temperature Adjuster): Internal aquastat dial setting the maximum high-limit temperature for the water exiting the tank. Since daily control is handled by the Nest Thermostat, this remains pre-set.

⚠️️ Tenant Safety & Usage Precautions

Safety & Precautions

Do NOT Run Without Water (Dry Firing Warning)

High Temperature Warning (Scald Hazard)

Do NOT Tamper with the Main Boiler Unit

🚨 Troubleshooting & Emergency Contact

Maintenance Contact

Landlord / Designer

Name: Michael O’dlee
Phone: 971-269-7800
Email / Text: michael@ondohl.com

Water Leaks

If you spot water under the boiler, set the Nest Thermostat to OFF and contact the landlord right away.

Breaker Trips [23, 25]

If the dedicated circuit breaker trips, do not force it back on repeatedly. Notify the landlord.

No Heat